1. It is unclear yet whether dispvm_netvm will be implemented in core3, but
probably not.
2. Remove tests for setting memory/cpu above host resouces - rejecting
those values at property set time would break backup restore on some
machines (when migrating from bigger to smaller system).
In some places full volume object was called, in others - just file
path. Since this function is also used in some volume init/teardown, use
path everywhere.
To successfully load all the data, proceed in order:
- set app.default_kernel
- load all templates
- set app.default_template
- load other VMs
- update network dependencies between VMs
- set other global properties
Apparently the most important (the only?) property required in offline
mode is "is_running". So let's patch it to return False and make sure
any other libvirt usage would result in failure.
Or maybe better simply returh False in vm.is_running, when libvirt
connection fails? But then it would not be possible to use offline mode
and have (some, probably unrelated) libvirtd running at the same time.
FixesQubesOS/qubes-issues#2008
Check directly vm.template, throwing AttributeError when not found.
There may be some value in converting it to more descriptive error, but
since that's mostly for internal users (not user facing actions) don't
bother for now.
QubesOS/qubes-issues#1842
It may make sense to create 'snapshot' volume out of already 'snapshot',
not only 'origin'. In pracice it will exactly the same as 'snapshot
connected directly to 'origin'.
QubesOS/qubes-issues#866
Make sure that even compromised frontend will be cut of (possibly
sensitive - like a webcam) device. On the other hand, if backend domain
is already compromised, it may already compromise frontend domain too,
so none of them would be better to call detach to.
QubesOS/qubes-issues#531
- Use full import paths in qvm-pool
- Add, Remove, Info and List options set `Namespace.command`. This fixes a crash
when `-o dir_path=/mnt/foo` is specified after `-a foo xen`.
- Remove `_List`
- Remove 'added pool' and 'removed pool' messages. Unix tools are quiet
- qvm-pool call app.save()
- Rename create_parser in get_parser
- Rename local_parser variables to just parser
- qvm-pool uses print_table
qrexec-daemon will start new processes for called services, which
include starting new DispVM, starting other required VMs (like backend
GPG VM). Having those processes as root leads to many permissions
problems, like the one linked below. So when VM is started by root, make
sure that qrexec-daemon will be running as normal user (the first user
in group 'qubes' - there should be only one).
QubesOS/qubes-issues#1768
- Remove old qvm-remove
- Remove a log line from Storage, because it prints confusing lines, like:
Removing volume kernel: /var/lib/qubes/vm-kernels/4.1.13-6/modules.img
Add the ability to handle commands having subcommands, like `qvm-block`
Split the ArgumentCheckVisitor in an OptionsCheckVisitor &
SubCommandCheckVisitor. The OptionsCheckVisitor checks options given
in a section named 'Options' (case insensitive), while the
SubCommandCheckVisitor dispatches on a section named 'Commands' (case
insensitive).
This also fixes finding the undocumented command arguments. The previous
solution with depart_document did not work. NodeVisitor does not dispatch to
depart_document() even if it's mentioned in the documentation.